Showing posts with label washer and dryers in your new home. Show all posts
Showing posts with label washer and dryers in your new home. Show all posts

Saturday, December 13, 2014

Do I have to vent my dryer outside?

Q:

Do I have to vent my dryer outside the home?

A:

There is a simple answer to this question and the answer is YES you do, you should always vent your dryer outside your home and you should never use a dryer without the vent working properly.

There are many reasons for venting your dryer outside the home. Here is a list of them;

• Dryer’s exhaust hot moist air, this air if not vented will create mold on the drywall behind the dryer and inside the room if it is small enough can severely damage the drywall in the entire space. Drywall does not like hot moist air.

• Dryer’s have a tendency to exhaust lint even though they have a vent lint trap. When lint collects in an enclosed space like behind a dryer it piles up and with the super heated hot air endlessly blowing on it from the dryer it can cause a fire. Many houses have burnt down because of an improperly vented dryer exhaust.

• New steam dryers are so hot that they cannot be vented with anything but stainless steel piping. The amount of hot steam that could be released behind the dryer with no venting could easily rot out the floor below the dryer.

• The vent dust can be harmful to people if it is blown into the air and inhaled. Clothes are made with a lot of chemicals on them and dryer sheets are also a chemical that aren’t meant to be breathed in through the air by humans.

• A non vented dryer is a lot louder than a vented dryer, the large amount of air that is produced by the dryer can make a lot of noise when not venting outside.

• The hot moist air can damage the underside of the dryer and the washer if it is next to it. The hot moist air becomes trapped under the appliances and has little to no air movement. This causes mold to form and appliances to rust over time.

When you are venting a dryer you should avoid using the plastic flexible piping, with enough hot air this plastic can overheat and melt causing damage and possibly a fire. The hood on the outside of the building should be made of metal and not plastic. The hood should also not have a metal screen in it like a lot of vent hoods, the screen will collect lint and could cause fires or lead to clogging of the pipe over time.

Rob Abbott
Village Builders Inc.

Saturday, May 7, 2011

What your builder needs to know about your new appliances!

When building or renovating a home, something that people have a tendency to over look telling there contractors about the appliances they plan to install in the house. When buying new appliances for your home there are certain things that you need to tell your contractor before he gets past the drywall stage of the project.
New washer and dryer's have some special needs that have to be addressed before installation. A growing trend is toward steam washer and dryers. This can require an extra water line run to the dryer and a metal exhaust pipe and hood instead of plastic. If there stackable the exhaust might need to be run up the wall to a certain height. Some dryer's have a down draft that has to be placed in the floor at a specific point so that the dryer can sit right over it. Some washer and dryer's have special shelving that has to be installed or want a laundry tub installed between them. If they are low slung machines you might want your contractor to build you a platform so that you don't have to bend over to assess the machines. Laundry counter tops need to be ended at a certain point so that they don't interfer with the installation or operation of the machines. Some people like to install washer/dryers on the second floor, so most contractor's will install a waterproof basin with a built in drain so that if the washing machine ever overflows, or the water connection fails the whole house wouldn't receive water damage.
In the kitchen, appliances have changed some much in the past couple of years contractor's are having trouble keeping up with the changing times. There now oven's that use steam to cook with, so they require a water line to be run to them. Ovens that are not just gas or electric are gas cook tops and electric ovens underneath. There are slide in ranges that require a normal stove plug, there are wall ovens that need the stoves to be hard wired by an electrican. There are kitchens with multiple ovens and multiple dishwashers. Kitchen's with 2 or 3 sinks are not special anymore they are becoming the norm. Some kitchens have the microwave mounted above the stove with a built in exhaust that needs to be piped out the wall, some have exhaust hoods that require large piping, specific dimensions and special electrical lines.
Fridges now have water dispensors and need water lines ran to them. Some kitchens have side by side stand up fridge/freezers. Alarm lines can be installed on these waterlines so that if they ever fail you are warned about it before it is to late.
Instant hotwater systems now can be installed underneath the counter next to the sink. These allow someone to have a cup of hotwater to make tea or coffee as easily as turning on a tap. This requires the contractor to install electrical under the sink, a water line under the sink and a water line leading to a tap that is next to the kitchen sink.
So when your planning your project and your contractor asks you if there's anything they need to know, think about the applainces that your planning to buy or have already bought. Because those applainces could cost you money near the end of the project if the contractor has to start opening holes in the walls or cieling to run extra water, electrical, gas, drain or exhaust lines.

Rob Abbott
Village builders Inc.
robabbott@villagebuilders.ca